Universal Level Switches
Level Transmitter

They work reliably and safely, even under harsh operating conditions.
| Level transmitter made from stainless steel, with housing, with a 4 – 20 mA output signal or 3-wire resistance signal. | |
| Transducer made from stainless steel, cable outlet with 3-wire resistance signal. | |
| Level transmitter made from stainless steel, with plug output with 4 – 20 mA output signal or 3-wire resistance signal. | |
| Level transmitter made from stainless steel, with digital display, 4 – 20 mA output signal and 2 limit values. | |
| Level transmitter made from polypropylene, with housing and 4 – 20 mA output signal or 3-wire resistance signal. | |
| Transducer made from polypropylene, cable outlet with 3-wire resistance signal. | |
| Level transmitter made from polypropylene, with 4 – 20 mA output signal or 3-wire resistance signal. | |
| Level transmitter made from polypropylene, with digital display, 4 – 20 mA output signal and 2 limit values. |
Type MG 01
Level transmitter made from stainless steel, with housing, with a 4 – 20 mA output signal or 3-wire resistance signal.
>> Data sheet, English (360.67KB)
>> Data sheet, German (367.09KB)
| Output | 4 - 20 mA or three-wire resistance signal |
| Pressure | max. 40 bar |
| Temperature | -30 to +120°C |
| Housing | Aluminum 75 x 80 x 57 mm, Aluminum 64 x 58 x 36 mm, Polycarbonate 80 x 82 x 55 mm |
| Medium density | ≥ 750 kg/m³ |
| Enclosure | IP66 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 6000 mm, (> 6000 mm on request) |
| Process connection | Standard: BSPP 1 ½", BSPP 2" flange DN50 PN16 |

Type MG 02
Transducer made from stainless steel, cable outlet with 3-wire resistance signal.
>> Data sheet, English (215.78KB)
>> Data sheet, German (222.27KB)
| Output | three-wire resistance signal |
| Pressure | max. 40 bar |
| Temperature | -30 to +120°C |
| Cable | PVC, Silicone |
| Medium density | ≥ 750 kg/m³ |
| Enclosure | IP54, optional IP68 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 6000 mm, (> 6000 mm on request) |
| Process connection | Standard: BSPP 3/8", BSPP 1/2" |

Type MG 03
Level transmitter made from stainless steel, with plug output with 4 – 20 mA output signal or 3-wire resistance signal.
>> Data sheet, English (322.37KB)
>> Data sheet, German (328.05KB)
| Output | 4-20 mA or three-wire resistance signal |
| Pressure | max. 40 bar |
| Temperature | -30 to +80°C |
| Connection | Couplar plug DIN 43650 |
| Medium density | ≥ 750 kg/m³ |
| Enclosure | IP66 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 6000 mm, (> 6000 mm on request) |
| Process connection | Standard: BSPP 1½", BSPP 2" flange DN50 PN16 |

Type MG 04
Level transmitter made from stainless steel, with digital display, 4 – 20 mA output signal and 2 limit values.
>> Data sheet, English (277.92KB)
>> Data sheet, German (283.65KB)
| Output | 4 - 20 mA and two-wire resistance signal |
| Pressure | max. 40 bar |
| Temperature | -30 to +80°C |
| Module | rotatable, with plug M12 |
| Medium density | ≥ 750 kg/m³ |
| Enclosure | IP65 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 6000 mm, (> 6000 mm on request) |
| Process connection | Standard: BSPP 1½", BSPP 2" flange DN50 PN16, other types on request |

Type MG 05
Level transmitter made from polypropylene, with housing and 4 – 20 mA output signal or 3-wire resistance signal.
>> Data sheet, English (336.61KB)
>> Data sheet, German (298.48KB)
| Output | 4-20 mA or three-wire resistance signal |
| Pressure | max. 3 bar |
| Temperature | -10 to +80°C |
| Housing | Polycarbonate 80 x 82 x 55 mm |
| Medium density | ≥ 500 kg/m³ |
| Enclosure | IP66 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 1500 mm, (> 1500 mm on request) |
| Process connection | Standard: BSPP 2", other types on request |

Type MG 06
Transducer made from polypropylene, cable outlet with 3-wire resistance signal.
>> Data sheet, English (244.72KB)
>> Data sheet, German (261.72KB)
| Supply voltage | 12 - 32 VDC |
| Output | three-wire resistance signal |
| Pressure | max. 3 bar |
| Temperature | -10 to +80°C |
| Cable | PVC |
| Medium density | ≥ 500 kg/m³ |
| Enclosure | IP54 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 1500 mm, (> 1500 mm on request) |

Type MG 07
Level transmitter made from polypropylene, with 4 – 20 mA output signal or 3-wire resistance signal.
>> Data sheet, English (280.72KB)
>> Data sheet, German (294.63KB)
| Output | 4 to 20 mA or three-wire resistance signal |
| Pressure | max. 3 bar |
| Temperature | -10 to +80°C |
| Connection | Couplar plug DIN 43650 |
| Medium density | ≥ 500 kg/m³ |
| Enclosure | IP66 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 1500 mm, (> 1500 mm on request) |

Type MG 08
Level transmitter made from polypropylene, with digital display, 4 – 20 mA output signal and 2 limit values.
>> Data sheet, English (324.42KB)
>> Data sheet, German (326.15KB)
| Output | 4 to 20 mA and 2 limit values |
| Pressure | max. 3 bar |
| Temperature | -30 to +80°C |
| Module | rotatable, with plug M12 |
| Medium density | ≥ 500 kg/m³ |
| Enclosure | IP65 |
| Accuracy | 12 mm |
| Tube length L | Standard: to 1500 mm, (> 1500 mm on request) |